o-s

IBM Guardium Appliance Port Usage

October 17, 2010
IBM Guardium Appliance port usage
Database Server to Collector Appliance:

Port

Protocol

Description

16016

TCP

Linux/UNIX only, both directions, STAP (the probe installed on the database servers) registration, heartbeat, & data

16018

TCP

Encrypted:Linux/UNIX only, both directions, STAP registration, heartbeat, & data

8075

UDP

Windows only, both directions, STAP heartbeat

9500

TCP

Windows only, DB Server to Collector, STAP registration & data

9501

TCP

Encrypted: windows only, DB Server to Collector, STAP registration & data
User to Guardium Appliance (Collector):

Port

Protocol

Description

22

TCP

User to appliance, cli connectivity

8443

TCP

User to appliance, gui connectivity
Guardium Appliance to SMTP server:

Port

Protocol

Description

25

TCP

Appliance to smtp server, email alerts
Guardium Appliance to SNMP server:

Port

Protocol

Description

161

UDP

Appliance to snmp server, snmp alerts

162

UDP

Both directions, snmp traps
Guardium Appliance to SYSLOG server:

Port

Protocol

Description

514

UDP

Appliance to syslog server, syslog alerts
22 – SSH – this is used for the cli interface & for copying files to/from the Guardium Appliance using SCP (e.g. when archiving data)
199 – SNMP queries -Allowing a Netcool/OpenView type system to knowthe Guardium Appliance is up & its status
8443 – HTTPS/SSL – used for the Web interface (always on SSL). The Web interface is used by the Guardium administrator and access to Guardium reports.
9500 (Windows) and 16016 (UNIX/Linux) – S-TAP – these are the ports on which the S-TAP (The probe installed on the database servers) sends the captured data to the Guardium Appliance(s).