IBM Guardium Appliance port usage
Database Server to Collector Appliance: Port
Protocol
Description
16016
TCP
Linux/UNIX only, both directions, STAP (the probe installed on the database servers) registration, heartbeat, & data 16018
TCP
Encrypted:Linux/UNIX only, both directions, STAP registration, heartbeat, & data 8075
UDP
Windows only, both directions, STAP heartbeat 9500
TCP
Windows only, DB Server to Collector, STAP registration & data 9501
TCP
Encrypted: windows only, DB Server to Collector, STAP registration & data User to Guardium Appliance (Collector): Port
Protocol
Description
22
TCP
User to appliance, cli connectivity 8443
TCP
User to appliance, gui connectivity Guardium Appliance to SMTP server: Port
Protocol
Description
25
TCP
Appliance to smtp server, email alerts Guardium Appliance to SNMP server: Port
Protocol
Description
161
UDP
Appliance to snmp server, snmp alerts 162
UDP
Both directions, snmp traps Guardium Appliance to SYSLOG server: Port
Protocol
Description
514
UDP
Appliance to syslog server, syslog alerts 22 – SSH – this is used for the cli interface & for copying files to/from the Guardium Appliance using SCP (e.g. when archiving data) 199 – SNMP queries -Allowing a Netcool/OpenView type system to knowthe Guardium Appliance is up & its status 8443 – HTTPS/SSL – used for the Web interface (always on SSL). The Web interface is used by the Guardium administrator and access to Guardium reports. 9500 (Windows) and 16016 (UNIX/Linux) – S-TAP – these are the ports on which the S-TAP (The probe installed on the database servers) sends the captured data to the Guardium Appliance(s).